imc STUDIO 2025 Software
imc STUDIO 2025 R4 will be included in standard delivery as of January 8, 2026, replacing the previous version. Including imc WAVE, imc STUDIO Monitor as well as the firmware and devices driver packages imc DEVICEcore 3.8 R3 and imc DEVICES 2.18 R3.
Reduced installer (2.3 GB)
Installation package with the typical products and components, without
imc FAMOS
Notes:
- The Update from imc STUDIO 2024 or older to imc STUDIO 2025 is not for free.
- When updating, please note the compatibility information in the What's new?
- In earlier versions of imc STUDIO 2025, the following problems may occur, which have been fixed as of revision 4:
- Issue: Measurements with imc ARGUSfit-CANFD modules are affected after internal data fifo wrap.
Description: If data of a CAN channel reaches its buffer size the internal buffer wrap algorithm increases the wrap count wrong. Therefore, the time derived information jumps into future and the error message "Measurement data overflow!" occurs. From there on the time information of the data samples “jumps” more into future on each buffer wrap.
Note: After preparing a measurement, the configured buffer size (buffer duration) is stated in imc STUDIO logbook as information. - Issue: Measurements with imc CANSASfit-HISO-T-8-2L at imc ARGUSfit-BASE insufficient temperature drift compensation
Description: If imc CANSASfit-HISO-T-8-2L is operated via imc CANSAS software, the modules temperature drift compensation works perfectly. But if imc CANSASfit-HISO-T-8-2L module is operated via imc ARGUSfit-BASE, that temperature drift compensation doesn’t work properly. This might lead to the following behavior: The accuracy is correct after preparing the measurement. If the module’s temperature increases, the measured temperature might increase too. - Issue: Measurements with imc ARGUSfit-BASE data overflow on internal storage media
Description: The internal storage of measurement data starts delayed by 5 minutes. If the internal buffer size is big enough all data will be stored correctly, but a high system load will occur. If the internal buffer size is less than 5min data will be lost for internal storage.
Note: After preparing a measurement, the configured buffer size (buffer duration) is stated in imc STUDIO logbook as information.
- Issue: Measurements with imc ARGUSfit-CANFD modules are affected after internal data fifo wrap.
What is new?
- imc STUDIO 2025What is new (PDF)?
- imc STUDIO Monitor 2025What is new (PDF)?
Tools
The following downloads are intended to help you with your application with imc STUDIO.
GSD file for PROFINET-IRT
Firmware and Driver: imc DEVICES and imc DEVICEcore
In the document "Firmware in imc STUDIO and imc WAVE" you will find detailed information about the following topics:
- Rules and guidelines on compatibility
- Operating multiple firmware versions simultaneously
- Installation procedures
- AddOns vs. Revisionsl
The update from imc DEVICES 2.6 or older is not for free.
Safety Certificate
Download Safety Certificate imcCert.cpt for secure access via https
imc devices having serial numbers 140000 and higher are supported, for which the associated activation code has been provided.
For transfer via a secure https-access, the "imcCert.cpt" certificate is necessary.
For the activation, please go to
Setup -> Configuration -> Device properties
into the Device configuration. Under Access protection (right column), you can navigate to the certificate. Please select the certificate "imcCert.cpt", which you have downloaded before and saved under the installation path under Firmware\Idif\, e.g. "C:\Program Files (x86)\imc\imc DEVICES 2.17 R2\Firmware\Idif".
This certificate is valid until 08.03.2026 and must be replaced upon expiration.
Repair Tool
- Please copy the Repair.exe and the dirrepair.bat in the corresponding archive with the defect files and then run the dirrepair.bat in a DOS-window. After that it should be possible to open the files.
Older Versions
An archive with earlier versions of imc STUDIO and imc WAVE (complete packages including their corresponding firmware and device drivers) is provided at: imc CLOUD.
Contact us
遨谱(上海)科技有限公司
免费热线电话:400-888-9826
北京办:丰台区航丰路1号院2号楼 时代财富天地A座 2511室, 100070
上海办:上海市闵行区申长路1398弄1号阿里中心T1座502室,201107
重庆办:渝北区赛迪路2号金山商业中心A座6楼, 410021
报价查询 : cnsales@imc-tm.com
订单查询 : cnorder@imc-tm.com
技术查询 : cnsupport@imc-tm.com
© imc Test & Measurement GmbH. All rights reserved. Privacy. Incident Reporting. Company Information.

