• Misst Temperaturen und Kleinspannungen auf bis zu 800 V Niveau

    High-voltage DAQ module

    Reliable and precise measurement of temperatures and low voltages

新款:高隔离温度测量模块测量高达800V

这款imc CANSAS-HCI8测量模块可以在不确定的或高共模电压(800V)下,安全、精确地测量温度和小电压信号。模块符合EN 61010设备安全标准,其隔离等级为800 V CAT I, 300 V CAT II。

Typical applications:

  • Temperature measurement on high-voltage components in electric and hybrid vehicles, e.g., batteries, fuel cells and supply circuits
  • Environments in which full personal safety must be guaranteed even in the event of a fault
  • Can be used for test benches as well as for mobile driving tests
  • Both in decentralized distributed and central measurement networks

HV-Moduls for Thermocouples

imc CANSASflex-HISO8-T

High voltage isolated CAN modules for the measurement of thermocouples

The measurement module imc CANSASflex-HISO8-T allows safe and precise measurement with 8 thermocouples (type K) which are mounted on high-voltage components with common mode voltage levels of up to 800 V. It is particularly suited for applications in the field of E-Mobility.

Highlights

  • Individually isolated measurement of temperatures (type K thermocouples) at a high common mode voltage level
  • Isolation: 800 V, 300 V CAT II (according to safety standard EN 61010)
  • Connector types: High-voltage-proof special connectors (LEMO):
    • 2x TE common plug (LEMO.2P 8-pin) or
    • 8x TE single plug (LEMO.2P 2-pin) or
  • Channel individual internal cold junction compensation

Typical applications

  • Temperature measurement on high-voltage components of hybrid and electric vehicles, such as batteries, fuel cells and supply systems.
  • Environments where personnel safety has to be ensured

HV-Modules for the measurement of PT100/1000 and low voltages

imc CANSASflex-HISO8-L

High voltage isolated CAN modules for the measurement of PT100/1000 and low voltages

The CAN-Bus measurement module imc CANSASflex-HISO8-L allows safe and precise measurement of PT100/1000, respectively low voltages, as well as differential voltages up to 100V on high-voltage components with common mode voltage levels of up to 800 V. It is particularly suited for applications in the field of E-Mobility.

Highlights

  • 8 chanels for measuring PT100/1000 or low voltages up to 100V
  • Isolation: 800 V, 300 V CAT II (according to safety standard EN 61010)
  • Connector types: High-voltage-proof special connectors (LEMO):
    • 4x PTx/voltage common plug (LEMO.2P 8-pin)
    • 8x PTx/voltage single plug (LEMO.1P 5-pin)

Typical applications

  • Temperature measurement on high-voltage components of hybrid and electric vehicles, such as batteries, fuel cells and supply systems.
  • Environments where personnel safety has to be ensured

imc CANSASflex-HISO-HV4

High voltage isolated CAN module for the measurement of differential voltages up to 800 V

The CAN-Bus measurement module imc CANSASflex-HISO-HV4 allows a differential volate measurment uo to 800 V on four channels.

Highlights:

  • Channel-wise isolated, galvanically-seperated inputs
  • High-volate isolation: channel/channel, channel/housing, channel/CAN and power supply
  • Isolation: 800 V, 300 V CAT II (according to safety standard IEC 61010)

Typical Applications:

  • Voltage measurment and tests on high-voltage components of hybrid and alectric vehicles
  • HV-batteries, ob-board high-voltage electrical systems, DC bus, charging converters, accessory subsystems
  • Evaluation of charge flows, energy balances and efficiencies
  • Environments wehere personnel safety has to be ensured

Connection box for high voltage (HV) modules

The HV connection box (HVBOX) serves as a flexible safety interface between the measuring point and the DAQ system. This allows sensors and test object instrumentation that were not originally designed to be HV-safe to be connected to the HVBOX and thus transformation to a fully HV-specified environment.

Features:

  • isolated screw terminals in polymer box
  • sensor cable entry via cable gland (PG)
  • serves as flexible and safe cabling interface to any arbitrary user cable
  • with 10 m special HV cable via LEMO.2P (Redel)
  • clear division between fully specified HV rated measurement module and connectors on one side – and custom and application specific cables and sensors on the other side
Top